Calculation and Design of Timber Constructions according to DIN 1052:2004-08 or EN 1995-1-1:2004 

The program RX-TIMBER calculates and designs glued-laminated beams, continuous beams and columns for the ultimate limit state and serviceability limit state according to DIN 1052: 2004-08 or EN 1995-1-1: 2004.
Also the fire protection proof according to DIN 4102 is possible.
Features of Module Glued-Laminated Beam

Calculation of different beam types:

  • parallel Calculation of different beam types: beam
  • monopitch roof beam
  • duopitch roof beam with straight bottom chord
  • arch beam
  • duopitch roof beam with inclined bottom chord and constant height
  • duopitch roof beam with inclined bottom chord and variable height
  • fish beam - parabolic
  • fish beam - linear with roundings in central area
Asymmetric layout and cantilevers.

Stiffening elements for transversal tension:
  • glued-in steel bars
  • steel bars with wood-screw threads
  • bonded solid wood or agglomerated wood strips
  • bonded agglomerated wood plates
Automatic determination of snow load according to DIN 1055: 2005, part 5.
Automatic determination of wind load according to DIN 1055: 2005, part 4.
Optimization of cross-sections.
Features of Module Continuous Beam

Calculation of different beam types:
  • simple beam, optionally with cantilever
  • continuous beam, optionally with cantilever
  • gerber beam, optionally with cantilever
Automatic determination of snow load according to DIN 1055: 2005, part 5.
Automatic determination of factors cpe, min and cpe, max for wind load
according to DIN 1055: 2005, part 4.
Reduction of shear force according to DIN 1052 10.2.9.
Redistribution of Moments according to DIN 1052 8.1 (6).
More Features of Both Modules

  • Simple definition of input data with graphics
  • Material library for both codes
  • Large library for permantent loads
  • Specification of service class and automatic classification to the live load category
  • Max. design, support forces and deformations
  • Short info about max. design
  • Colored scales in result tables
  • Direct export of data to MS Excel
  • DXF interface for data building in CAD
  • Program languages: German, English or Czech
  • Printout report with input and reduced result data
Features of Module Column

  • Calculation of different column types:
    - hinged column, optionally with elastic restraint of footing
    - bracket, optionally with elastic restraint of footing
  • Calculation of two cross-sections:
    - rectangular
    - round
  • Simple definition of input data with graphics
  • Material library for both codes (coniferous timber, gluelam timber, leafy timber)
  • Specification of service class and automatic classification to the live load category
  • Automatic determination of wind and snow loads according to DIN 1055: 2005
  • Detailed parameters for fire protection
  • Definition of deflection limit values for the serviceability limit state
  • Special settings for glulam according to annotations in DIN 1052:2008-04, table F.9
  • Max. design, support forces and deformations
  • Short info about max. design
  • Colored scales in result tables
  • Printout report with input and reduced result data
Geometry Data in Continuous Beam Control Parameters in Continuous Beam Effective Lengths in Continuous Beam Fire Protection Proof in Continuous Beam

Geometry Data in Continuous Beam

Control Parameters in Continuous Beam

Effective Lengths in Continuous Beam

Fire Protection Proof in Continuous Beam

Deformations and Oscillation Check Material Library General Data in Module Column Load Data in Module Column

Deformations and Oscillation Check

Material Library

General Data in Module Column

Load Data in Module Column

Support Forces Info about Cross-Section Result Diagram on Member Printout Report

Support Forces

Info about Cross-Section

Result Diagram on Member

Printout Report

QUICKSEARCH

Note

You can find more information about RX-TIMBER here:


RX-TIMBER 4.xx demo version
Try out RX-TIMBER yourselves and download a free demo version.
[Page with downloads...]

Request information
Download our new brochure about all Dlubal products in the PDF format. Alternatively, we can send you the brochure including a demo DVD directly by mail.
[Free materials...]

Your basket

1x RF-STEEL AISC 4.xx Additional license
742.50 €
1x RF-STEEL SIA 4.xx
1,650.00 €
1x SUPER-LC 7.xx Additional license
250.00 €
1x PLATE-BUCKLING 7.xx
1,000.00 €
Total
3,642.50 €

Price Information

Net prices in €
1st license
RX-TIMBER Package 1,650.00
Additional license
RX-TIMBER Package 742.50
Selection of Beam Type and Material in Glued-Laminated Beam
Selection of Beam Type and Material in Glued-Laminated Beam
Data for Lateral Buckling
Data for Lateral Buckling
Stiffening Elements for Transversal Tension
Stiffening Elements for Transversal Tension
Define Loads in Glued-Laminated Beam
Define Loads in Glued-Laminated Beam
Load Combinations in Results
Load Combinations in Results
Results of All Designs Including Details
Results of All Designs Including Details
Result Diagram on Member
Result Diagram on Member
Information about Wind Zones in Germany
Information about Wind Zones in Germany
Graphics and Details of Load Cases
Graphics and Details of Load Cases
Exported Data in MS-Excel
Exported Data in MS-Excel