Due to the deterioration of some timber footbridges on the pedestrian and cycle path of the Seriana Valley in the province of Bergamo, Italy, it was necessary to refurbish them with more durable materials. Therefore, the mountain community of the Seriana Valley commissioned Studio Rota Nodari of Alzano Lombardo to design and manage the works for the replacement of the bridge over the Serio river between the municipalities of Cene and Gazzaniga, Italy.
Investor |
Seriana Valley Mountain Community |
Structural Design |
Studio Rota Nodari |
Construction Works |
Cosmetics by Fantoni Srl |
Model Parameters
Model
Work Description
The structure is a double-span bridge of the 3rd category, with a pile in the riverbed and a total span of 226.38 ft, achieved using painted steel box girders, and a deck made of recycled plastic material (WPC).
The design of the footbridge involved prior analysis of the existing reinforced concrete structures by means of non-invasive instrumentation using a calibrated spring sclerometer and ultrasound according to the SonReb methodology, as well as a cover meter. The structural analysis and design based on the original design documentation has shown that the strength values are compatible with the actions transmitted by the new structure; therefore, reinforcement of the supporting structures was not necessary.
The company Cosmet SrL was in charge of the construction works, the disassembly and disposal of the timber footbridge, and the assembly of the new structure. To optimize the transportation costs and reduce the assembly time (within two weeks), the structure is composed of elements with a maximum length of 45.93 ft, assembled on site using bolted joints.
Project Location
Keywords
Bridge Steel footbridge Bolted joints
Write Comment...
Write Comment...
Contact Us
Do you have further questions or need advice? Contact us via phone, email, chat, or forum, or search the FAQ page, available 24/7.

New
CSA S16:19 Stability Considerations and the New Annex O.2
The CSA S16:19 Stability Effects in Elastic Analysis method in Annex O.2 is an alternative option to the Simplified Stability Analysis Method in Clause 8.4.3. This article will describe the requirements of Annex O.2 and application in RFEM 6.
- The load distribution on my members looks different when using the Load Transfer surface vs. the Load Wizards. What is the reason?
- My beam has a continuous lateral support and therefore lateral torsional buckling (LTB) is not a concern. How do I define the effective length?
- I received an error message “Surface of incompatible type... (Surface in upper plane of building story must be of ‘Load transfer’ type)” when running the calculation. What is the reason?