371x
000374
2019-06-13

[EN] FAQ 003159 | When calculating a connection using the FRAME‑JOINT Pro add-on module, a message ...

Question:
When calculating a connection using the FRAME‑JOINT Pro add-on module, a message appears sayng that the value is out of the valid range (existing value: 160, minimum value 200). What does this message mean?

Answer:
This message is usually displayed when the member dimensions do not correspond. 
In the example model, the beam has a flange width of 200 mm, and the column support, of 160 mm.

This joint is not valid in the add-on module, as the flange width of the column should be at least as large as the flange width of the structural element to be connected. As soon as the cross-sections are defined according to this rule, the connection design can also be performed.