FAQ 004427 | Which formula is used in the RF‑/TOWER Loading add-on module to calculate the first natural frequency for the determination of the structure coefficient?

Easily learn how to work with the Dlubal Software programs

  • Dlubal Software | Videos

Video

First Steps with RFEM

First steps

We provide hints and tips to help you get started with the basic program RFEM.

05/26/2020

001387

Andreas Niemeier

Please accept Marketing Cookies to watch this video.

Question

Which formula is used in the RF‑/TOWER Loading add-on module to calculate the first natural frequency for the determination of the structure coefficient?

Answer

The first natural frequency is required to determine the structure coefficient. It is not determined by using a generalized formula, but the integrated eigenvalue solver RF‑/DYNAM, taking into account the real mass distribution and displaying the results in Column A of Table 2.3.