FAQ 002408 EN-US 02/13/2019

Markus Baumgärtel Add-on Modules CONCRETE RF-CONCRETE

Why is the field "Most economical reinforcement for crack width detection" greyed out in RF-CONCRETE Members or CONCRETE?

Answer

The option "Find the most economical reinforcement for crack width detection" is greyed out because the minimum reinforcement As, min was not selected.

For the most economical reinforcement to be found, several "detection forms" must be activated.

These would be z. B .:

  • Direct calculation of the crack width wk
  • As, min + lim ds
  • As, min + lim sl
As soon as several "verification formats" are available, the option can also be selected (see Figure 1).

Keywords

Most economical reinforcement crack width detection

Reference

Contact us

Contact Dlubal Software

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.