What to do if the plausibility check fails: "Line support type" Wall in Z "on line no. ... is not connected to any horizontal surface ".

Answer

The line storage type wall is actually intended for ceiling panels, the z. B. rest elastically bedded on a masonry wall. Because of this, this tool is only allowed for horizontal surfaces. The spring is calculated from the wall and used in the calculation.
If the surfaces are not horizontal, then the spring must be entered manually.
If you want to use the springs from the wall as a reference for your own inputs, then you can first define the wall and then remove the hook at the wall. The calculated springs are then retained in the input fields and can be edited.