The increase of the material coefficient epsilon in the details - carrying capacity is grayed out, why?

Answer

According to EN 1993-1-1, an increase in the material coefficient based on the applied stresses is only possible if the proofs of stability are not provided with replacement certificates. As the substitute bar proofs are activated by default in the following tab "Stability", this checkbox is greyed out. After deactivating the replacement proofs, this checkbox is enabled and activated by default.

Keywords

Coefficient of material Epsilon Eurocode 3 Stability Load capacity Cross section classification Steel construction Steel EC3 Substitute bill proving