New
FAQ 002579 EN-US 03/05/2019

Wieland Götzler Add-on Modules STEEL EC3 RF-STEEL EC3

I have a profile where local bumps can be neglected. Can I manually classify the cross-section and thus bypass the cross-section class 4?

Answer

A manual cross-section classification is possible in screen 1.3 Cross sections. For general cross sections the cross section classes 3 and 4 are available and for all common profiles all cross section classes 1 to 4.

Keywords

Cross-section classification Eurocode 3 EC3 steel construction class 4