Can I combine the nonlinear calculation in RF-CONCRETE NL with the determination of foundation coefficients in RF-SOILIN?

Answer

This should be possible if only one combination is used in the non-linear calculation. The theoretical background is that RF-SOILIN can not consider several situations in parallel with different foundation coefficients. Only one case can be considered at a time. If several load situations are considered in RF-CONCRETE NL, several different stiffnesses theoretically result. In connection with RF-SOILIN, this leads to a contradictory situation.

Keywords

foundation construction soil-structure interaction state II nonlinear

Downloads

Contact us

Contact Dlubal Software

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.