This article was translated by Google Translator View original text

I would like to perform a hot design with the EC3 module. Is it possible to intervene in the program so that one can be used instead of the standard temperature curves?

Answer

The method according to EC 3 can only be used for the temperature curves from EN 1990-1-2. In addition, with the simplified calculation of the steel temperature in the EC 3-1-2, it is only possible to take into account increasing temperature profiles; a drop in the temperature is not available in this simplified calculation. However, it is also possible to use direct steel temperatures in the program (see Figure 1).