For a cross-section in my model, the STEEL EC3 add-on module uses the incorrect yield strength depending on the thickness of the structural component. What can be the cause?

Answer

This effect usually occurs in SHAPE-THIN cross-sections. When modeling the cross-sections, make sure that the input for heights and thickness of the elements is not reversed (see Figure 1).