For RF-CONCRETE Columns, I get a design ratio > 1 for the fire resistance design. How can the design be carried out in the add-on module?

Answer

The add-on module determines the required reinforcement for the ultimate limit state. The fire resistance design is performed as design based on the determined reinforcement. The reinforcement will not be increased in this context. If the design is not fulfilled, you can either define a higher reinforcement manually or adjust the concrete cover to prevent the applied reinforcement from being damaged too much by the effects of fire.

Keywords

Fire resistance Fire protection design Fire resistance design

Downloads

Contact us

Contact Dlubal Software

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.