How is the rotational stiffness of a buckling stiffener determined in PLATE‑BUCKLING?
Answer
In PLATE‑BUCKLING, the rotational stiffness of a stiffener is determined on the basis of the sketch shown in the figure including formulas according to ECCS Design of Plated Structures, Fig. 2.77.
Rotational Stiffness of Stiffener with Same Distances to Next Stiffener
cθ | Rotational stiffness of the buckling stiffness |
E | Modulus of elasticity |
t | Component thickness in the buckling panel |
b | Distance to the next stiffener |
Rotational Stiffness of Stiffener with Different Distances to Next Stiffener
cθ | Rotational stiffness of the buckling stiffness |
E | Modulus of elasticity |
t | Component thickness in the buckling panel |
b1 | Distance to the next stiffener on one side |
b2 | Distance to the next stiffener to the other side |
Image 01 - Sketch of Buckling Panels According to ECCS Design of Plated Structures, Fig 2.77
Keywords
Rotational stiffness Stiffener Transverse stiffener Longitudinal stiffener Torsional buckling
Downloads
Contact us
Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.
Recommended Events
Eurocode 3 | Steel structures according to DIN EN 1993-1-1
Online Training 05/06/2021 8:30 AM - 12:30 PM CEST
Designing Cold-Formed Steel Sections According to Eurocode 3
Webinar 04/30/2020 3:00 PM - 3:45 PM CEST
Membrane Structures with Wind Loads from CFD Wind Simulation
Webinar 03/24/2020 3:00 PM - 4:15 PM CET
Dlubal Webinar: Design of Steel Structures According to EC 3 | Part 2: Stability Analysis, Design
Webinar 12/01/2017
Dlubal Webinar: Design of Steel Structures According to EC 3 | Part 1: Modeling, Loading
Webinar 11/24/2017 3:00 PM - 4:00 PM CET
Videos
Models to Download
Knowledge Base Articles

New
CSA S16:19 Stability Considerations and the New Annex O.2
Structure stability is not a new phenomenon when referring to steel design. The Canadian steel design standard CSA S16 and the most recent 2019 release is no exception.
Screenshots
Product Features Articles

SHAPE-THIN determines the effective cross-sections according to EN 1993-1-3 and EN 1993-1-5 for cold-formed sections. You can optionally check the geometric conditions for the applicability of the standard specified in EN 1993‑1‑3, Section 5.2.
The effects of local plate buckling are considered according to the method of reduced widths and the possible buckling of stiffeners (instability) is considered for stiffened sections according to EN 1993-1-3, Section 5.5.
As an option, you can perform an iterative calculation to optimize the effective cross-section.
You can display the effective cross-sections graphically.
Read more about designing cold-formed sections with SHAPE-THIN and RF-/STEEL Cold-Formed Sections in this technical article: Design of a Thin-Walled, Cold-Formed C-Section According to EN 1993-1-3.
Frequently Asked Questions (FAQ)
- In PLATE‑BUCKLING, the reduction factor due to column buckling χc is calculated using the modified slenderness of the sheet metal ${\overline{\mathrm\lambda}}_{\mathrm p}$. Why is it not calculated using the slenderness of the equivalent compression member ${\overline{\mathrm\lambda}}_{\mathrm c}$ ?
-
Why are my steel members not being designed for stability in RF-STEEL AISC?
- My section is classified as Class 4 and non-designable in RF-/STEEL CSA. However, my manual calculation shows a different class. Why the difference?
- Can the properties, such as B. the cross -section or the surface thickness as well as the material of a surface of an existing element for a new element?
- I have defined temperature loads, strain loads, or a precamber. As soon as I modify stiffnesses, the deformations are no longer plausible.
- I am trying to manually check the deformations from the CRANEWAY add-on module. However, I obtain great deviations. How to explain the differences?
- What should be considered when using a failure of columns under tension in the RF‑/DYNAM Pro – Equivalent Loads add-on module?
- Why is there no stability analysis displayed in the results despite the activation of the stability analysis in RF‑/STEEL EC3?
- How can I model and design a crane runway girder with Dlubal Software?
- Is it possible to set user-defined values when viewing solid stress results?
Customer Projects
Associated Products
PLATE-BUCKLING 8.xx - Stand-Alone
Stand-Alone Program
Plate buckling analysis of rectangular plates with or without stiffeners
900.00 USD