1394x
001325
2017-03-17

Effective Concrete Tensile Strength at Time of Cracking

As of program version 5.06, you can use the option to adjust the effective concrete tensile strength fct,eff,wk at the time of cracking. At the start of the SLS design, the program checks whether the internal forces can cause cracks in the concrete. For this, the effective concrete tensile strength at the time of cracking is applied. You can adjust the strength via the factor. The calculation details display the adjusted value.
You can adjust the effective concrete tensile strength fct,eff,wk in Window 1.6 Reinforcement, "Serviceability" tab.

Author

Mr. Langhammer is responsible for development in the area of reinforced concrete structures, and provides technical support to our customers.

Links