  1. Approximate Consideration of P-Delta Effects with Amplification Factors in RF-DYNAM Pro - Equivalent Loads

    P-Delta Effects and Seismic Design According to the ASCE 7-16 and NBC 2015

    As gravity loads act on a structure, lateral displacement occurs. In turn, a secondary overturning moment is generated as the gravity load continues to act on the elements in the laterally displaced position. This effect is also known as "P-Delta (Δ)." Sect. 12.9.1.6 of the ASCE 7-16 Standard and the NBC 2015 Commentary specify when P-Delta effects should be considered during a modal response spectrum analysis.

  2. Figure 01 - Structural System

    Nonlinear Time History Analysis Using the Example of a Tower Structure with Prestressed Cables

    There can be numerous nonlinearities in a structural system. In order to model them realistically in a dynamic analysis, the RF-DYNAM Pro - Nonlinear Time Histoey add-on module was developed. To explain how the add-on module works, the procedure is described below with an example.

  3. Figure 01 - External Pressure Coefficients, Cp, for Domed Roofs with a Circular Base (according to Figure 27.3-2 [1])

    Wind Loads on Circular Dome Roof Structures According to ASCE 7-16

    When it comes to wind loads on building type structures per the ASCE 7, numerous resources can be found to supplement design standards and aid engineers with this lateral load application.  However, engineers may find it more difficult to find similar resources for wind loading on non-building type structures.  This article will examine the steps to calculate and apply wind loads per the ASCE 7-16 on a circular reinforced concrete tank with a dome roof.
  4. Structural Modeling in RFEM

    Determination of Story Drift According to ASCE 7-16 Under Seismic Loads

    The story drift of a building provides valuable information about its structural behavior under seismic loads.
  5. Determination of the Maximum Horizontal and Vertical Loads to Calculate the Stability Coefficient

    Consideration of P-Delta Effects (Second-Order Analysis) in the Response Spectrum Analysis According to ASCE 7-16

    RFEM offers the option to perform a response spectrum analysis according to ASCE 7-16. This standard describes the determination of seismic loads for the US-American market. It might happen that the so-called P-Delta effect has to be considered due to the stiffness of the entire structure to be able to calculate the internal forces and carry out the design.
  6. Figure 01 - Generation of Result Beam

    Determination of Transversal Shear Under Seismic Loads

    In RF-/DYNAM Pro - Equivalent Loads, the equivalent seismic loads can be calculated according to different standards. By calculating the equivalent loads for each eigenvalue, it is not directly possible to obtain the transversal shear for each story to perform an analysis afterwards. The following example describes the option to calculate the transversal shear quickly and efficiently.
  7. Signed Results Using the Dominant Mode

    Signed Results Using the Dominant Mode

    In RF-/DYNAM Pro - Equivalent Loads, a signed result option in accordance to the dominant eigenmode is available since version X.06.3039. For the modal combination of results corresponding to the single eigenvalues a quadratic combination rule has to be used, in RFEM and RSTAB the SRSS and the CQC rule are available. It is only allowed to combine results not loads directly. The reason are the mode shapes which are arbitrarily scaled and signed.

  8. Settings of the Time Course Monitor

    Settings of the Time Course Monitor

    The Time Course Monitor displays results of a time history analysis from RF‑/DYNAM Pro - Forced Vibrations. The graphic can be adjusted in the settings. This can be reached via the right click in the context menu. For example you can activate or deactivate the grid in the graphic. Those changes are overtaken into the printout report when you print the graphic.

  9. Complete Quadratic Combination (CQC) Rule in RF-DYNAM Pro - Equivalent Loads

    Quadratic Combination Using CQC Rule

    In RF‑/DYNAM Pro - Equivalent Loads the CQC (Complete Quadratic Combination) rule is available since version X.06.3039.

  10. 1 - Reduction of building on cantilever structure. The individual mass points represent storeys. Displacement due to compression normal forces shown in (a) is converted to (b) overturning moments or lateral loads [2].

    Considering Second-Order Theory in Dynamic Analysis

    For the ultimate limit state design, EN 1998‑1 [1], Section 2.2.2 and 4.4.2.2, require the calculation considering the second‑order theory (P‑Δ effect). This effect need not be taken into account only if the interstorey drift sensitivity coefficient θ is less than 0.1.

1 - 10 of 21

Contact us

Contact Dlubal Software

Do you have questions or need advice?
Contact our free e-mail, chat, or forum support or find various suggested solutions and useful tips on our FAQ page.

(267) 702-2815

info-us@dlubal.com

Customer Support 24/7

Knowledge Base

In addition to our technical support (e.g. via chat), you’ll find resources on our website that may help you with your design using Dlubal Software.

First Steps

First steps

We provide hints and tips to help you get started with the main programs RFEM and RSTAB.

Powerful and Capable Software

“I think the software is so powerful and capable that people will really value its power when they get properly introduced to it.”