RF-/TIMBER Pro | Features

Product Feature

  • Full integration in RFEM/RSTAB with import of all relevant information and internal forces
  • For design according to EN 1995-1-1, the following National Annexes are available:
    •  ÖNORM B 1995-1-1:2015-06 (Austria)
    • Belgium NBN EN 1995-1-1/ANB:2012-07 (Belgium)
    • Bulgaria BDS EN 1995-1-1/NA:2012-02 (Bulgaria)
    • Cyprus CYS EN 1995-1-1/NA:2011-02 (Cyprus)
    •  CSN EN 1995-1-1/NA:2007-09 (Czech Republic)
    •  DK EN 1995-1-1/NA:2011-12 (Denmark)
    •  SFS EN 1995-1-1/NA:2007-11 (Finland)
    •  DIN EN 1995-1-1/NA:2013-08 (Germany)
    •  UNI EN 1995-1-1/NA:2010-09 (Italy)
    •  I.S. EN 1995-1-1/NA:2010-03 (Ireland)
    •  LVS EN 1995-1-1/NA:2012-05 (Latvia)
    •  LST EN 1995-1-1/NA:2011-10 (Lithuania)
    •  LU EN 1995‑1‑1/NA:2011‑09 (Luxembourg)
    •  NEN EN 1995-1-1/NB:2007-11 (Netherlands)
    •  NS EN 1995-1-1/NA:2010-05 (Norway)
    •  NF EN 1995-1-1/NA:2010-05 (France)
    •  PN EN 1995-1-1/NA:2010-09 (Poland)
    •  NP EN 1995-1-1 (Portugal)
    •  SR EN 1995-1-1/NB:2008-03 (Romania)
    •  STN EN 1995-1-1/NA:2008-12 (Slovakia)
    •  SIST EN 1995-1-1/A101:2006-3 (Slovenia)
    •  UNE EN 1995-1-1/AN:2016-04 (Spain)
    •  SS EN 1995-1-1 (Sweden)
    • United Kingdom BS EN 1995-1-1/NA:2009-10 (United Kingdom)
  • Extensive material library in compliance with the EN, SIA, and DIN standards
  • Design of circular, rectangular, and user-defined composite cross-sections (also hybrids)
  • Specific classification of a structure in service classes (SECL) and actions in load duration classes (LDC)
  • Design of members and sets of members
  • Stability analysis according to the Equivalent Member Method or the second-order analysis
  • Determination of governing internal forces
  • Icon informing about successful or failed design
  • Visualization of the design criterion on RFEM/RSTAB model
  • Automatic cross-section optimization
  • Parts lists and quantity surveying
  • Data export to MS Excel
  • Free setting of fire resistance classes and charring rates as well as free selection of charring sides
  • Fire resistance designs in the selected standard according to:
    •  EN 1995-1-2
    •  SIA 265:2012 + SIA 265-C1:2012
    •  DIN 4102-22:2004
  • Import of buckling lengths from the RF-STABILITY/RSBUCK add-on module
  • Design of tapered members according to the previously defined cut-to-grain angle
  • Ridge design and analysis of transversal tension stresses for defined ridges
  • Design of curved members and sets of members

Contact us

Contact Dlubal Software

Do you have any questions or need advice?
Contact us or find various suggested solutions and useful tips on our FAQ page.

(267) 702-2815

info-us@dlubal.com

RFEM Timber Structures
RF-TIMBER Pro 5.xx

Add-on Module

Timber design according to Eurocode 5, SIA 265 and/or DIN 1052

Price of First License
1,120.00 USD