The design is carried out according to EN 1993-1-8 and EN 1993-1-1. It is assumed that the internal forces are directly located in the defined node. In case of beam-column connections, additional eccentricities thus appear to the connection level which have to be considered in the calculation. Besides the design of the sufficient ultimate limit state of the connection, a calculation and classification of the connection with regard to stiffness is performed.