857x
000087
2003-07-27

Therme Meran Swimming Pool Hall in South Tyrol, Italy

The structure of the steel hall for a swimming pool at Therme Meran spa consists of rigid rectangular hollow section columns bearing a roof structure rigid in two directions. The model was calculated according to the second-order analysis, considering inclination and precamber.

The structure consists of rigid rectangular hollow section columns bearing a trussed roof structure.

The model was calculated according to the second-order analysis, considering inclination and precamber.

In addition, the hollow section columns were reinforced and concrete-lined, and analyzed as composite columns in order to reach the fire resistance class of F30 and increase the horizontal stiffness of the model.

Structural Engineering Frener & Reifer Metallbau GmbH
Brixen, Italy
www.frener-reifer.com
Architect Matteo Thun
Milan, Italy
www.matteothun.com
Investor Terme Merano/Therme Meran
Meran, Italy
www.termemerano.it


Project Specifications

Do you have any questions?