New Roofing for Entrance Gates of Messe Frankfurt
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Steel Stress Analysis of North Roof in RSTAB (© Bollinger + Grohmann)
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
New Roofing for Entrance Gates of Messe Frankfurt
Steel Stress Analysis of North Roof in RSTAB (© Bollinger + Grohmann)
2024-03-09
011786
  • RFEM 5
  • RSTAB 8

New Roofing for Entrance Gates of Messe Frankfurt

Used in
  • Roofing with Circular Steel Roofs
3D Model
No Download Possible Customer Project / View Only
More About 3D Model
  • Roofing with Circular Steel Roofs
Specifications
Number of Nodes 298
Number of Members 567
Number of Load Cases 10
Number of Load Combinations 14
Number of Result Combinations 6
Total Weight 67,049 t
Dimensions (Metric) 39.335 x 23.128 x 5.174 m
Dimensions (Imperial) 129.05 x 75.88 x 16.98 feet
Program Version 8.02.00
Share
2024-05-30
012234
  • Steel Structures
Steel Stress Analysis of North Roof in RSTAB (© Bollinger + Grohmann)
Used in
  • New Roofs Above Gates of Exhibition Grounds in Frankfurt, Germany
3D Model
No Download Possible Customer Project / View Only
More About 3D Model
  • Roofing with Circular Steel Roofs
Specifications
Number of Nodes 298
Number of Members 567
Number of Load Cases 10
Number of Load Combinations 14
Number of Result Combinations 6
Total Weight 67,049 t
Dimensions (Metric) 39.335 x 23.128 x 5.174 m
Dimensions (Imperial) 129.05 x 75.88 x 16.98 feet
Program Version 8.02.00
Share