Model of Stadium Roof Made of Membranes
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Wind Simulation as Special Solution Add-on
Wind Simulation as Analysis Type
Wind Simulation Tab
User-Defined Wind Profile
Wind Simulation Analysis Settings
Wind Tunnel Dimensions
Results: Surface Pressure
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Results: Pressure Field
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Results: Velocity Field
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Results: Velocity Vectors
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Results for Wind Load Case in RFEM 6
  • 3D Viewer
  • 3D Viewer | Babylon
  • Virtual Reality
Model of Stadium Roof Made of Membranes
Wind Simulation as Special Solution Add-on
Wind Simulation as Analysis Type
Wind Simulation Tab
User-Defined Wind Profile
Wind Simulation Analysis Settings
Wind Tunnel Dimensions
Results: Surface Pressure
Results: Pressure Field
Results: Velocity Field
Results: Velocity Vectors
Results for Wind Load Case in RFEM 6
2024-05-30
029154
  • RFEM 6
  • Tensile Membrane Structures

Model of Stadium Roof Made of Membranes

Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share
2024-05-30
029155
  • RFEM 6
  • Wind Simulation & Wind Load Generation
Wind Simulation as Special Solution Add-on
  • Wind Simulation
  • Add-Ons
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029156
  • RFEM 6
  • Wind Simulation & Wind Load Generation
Wind Simulation as Analysis Type
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029157
  • RFEM 6
  • Wind Simulation & Wind Load Generation
Wind Simulation Tab
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029158
  • RFEM 6
  • Wind Simulation & Wind Load Generation
User-Defined Wind Profile
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029159
  • RFEM 6
  • Wind Simulation & Wind Load Generation
Wind Simulation Analysis Settings
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029160
  • RFEM 6
  • Wind Simulation & Wind Load Generation
Wind Tunnel Dimensions
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
Share
2024-05-30
029161
  • Tensile Membrane Structures
  • Wind Simulation & Wind Load Generation
Results: Surface Pressure
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share
2024-05-30
029162
  • Tensile Membrane Structures
  • Wind Simulation & Wind Load Generation
Results: Pressure Field
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share
2024-05-30
029163
  • Tensile Membrane Structures
  • Wind Simulation & Wind Load Generation
Results: Velocity Field
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share
2024-05-30
029164
  • Tensile Membrane Structures
  • Wind Simulation & Wind Load Generation
Results: Velocity Vectors
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share
2024-05-30
029165
  • RFEM 6
  • Tensile Membrane Structures
  • Wind Simulation & Wind Load Generation
Results for Wind Load Case in RFEM 6
Used in
  • Wind Load Application in RWIND 2 for Precise Structural Analysis
3D Model
More About 3D Model
  • Model of Membrane Stadium Roof
Specifications
Number of Nodes 193
Number of Lines 456
Number of Members 456
Number of Surfaces 96
Number of Solids 0
Number of Load Cases 4
Number of Load Combinations 0
Number of Result Combinations 0
Total Weight 684.410 t
Dimensions (Metric) 294.612 x 63.730 x 288.000 m
Dimensions (Imperial) 966.57 x 209.09 x 944.88 feet
Share