Tab 'Standard parameter' for fire protection configuration according to EN 1995
Tab 'Standard parameter' for fire protection configuration according to EN 1995
2025-05-28
056807
  • RFEM 6

Tab 'Standard Parameter' for Fire Protection Configuration According to EN 1995

Tab 'Standard parameter' for fire protection configuration according to EN 1995

The image shows the 'Standard parameter' register within a fire protection configuration according to EN 1995. Users can check and, if necessary, adjust charring rates for different wood types here. Such adjustments are crucial for precise fire design in timber structures. The correct configuration of the standard parameters enables a better understanding of the effects of fire exposure on different wood types.
  • Fire design
  • standard parameters
  • charring rate
Share