2026-06-22
063269
Design Ratio and Rotational Stiffness of JD2 Model
Table showing ultimate limit state design checks for plate, bolt, and weld components, including calculated rotational stiffness values for connected members.
The results table displays the design verification for Design Situation DS1 according to ULS (STR/GEO) under loading CO1. The design check ratios are given for the end plate, the fasteners, and the fillet weld, all satisfying the ultimate limit state requirements.