RFEM 6 Design Check Details SD0208 – Punching Shear Check of Foundation Plate
Design check details SD0208 punching shear check foundation plate ACI 318 utilization 0.195
Screenshot of the design check details in RFEM 6 for check SD0208 per ACI 318 (2019): two-way (punching) shear check of the foundation plate without shear reinforcement according to section 22.6.1.2. The design check ratio η is 0.195.