RFEM 6 Design Check Details SD0216.01 – Required Bottom Longitudinal Reinforcement in x-Direction
Design check details SD0216.01 required bottom longitudinal reinforcement x-direction ACI 318 utilization 0.862
Screenshot of the design check details in RFEM 6 for check SD0216.01 per ACI 318 (2019): required longitudinal reinforcement on the foundation plate into the x-direction on the bottom side. The screenshot shows the calculation of the required reinforcement area and a design check ratio of 0.862.