Tab 'Surfaces' for fire resistance configuration according to CSA
Tab 'Surfaces' for fire resistance configuration according to CSA
2026-09-28
065142
  • RFEM 6
  • Timber Design for RFEM 6
  • Timber Structures
    • EN 1995-1-1
    • CSA O86

Tab 'Surfaces' for Fire Resistance Configuration According to CSA

Tab 'Surfaces' for fire resistance configuration according to CSA

The dialog box shows the fire design parameters of a surface. The required fire resistance duration is 30 minutes, with the charring rules for walls and surface components activated at β₀ = 0.65 mm/min for all layers. The user interface allows the definition of a layer with zero strength and a threshold thickness of 0.118 inch for neglecting the reduced layer. The fire exposure is set for top (–z) and bottom (+z) with an initial protection at the bottom with a protection time tf of 15 minutes. The calculation is performed according to the Canadian standard CSA O86.
  • Fire design
  • Fire resistance
  • Plasterboard