Dialog Edit Member with Shear Reinforcement tab, stirrup parameters, and cross-section display of the shear reinforcement in RFEM
Dialog Edit Member with Shear Reinforcement tab, stirrup parameters, and cross-section display of the shear reinforcement in RFEM
2026-11-13
065648
  • RFEM 6
  • RSTAB 9
  • Concrete Design for RFEM 6
    • Concrete Design for RSTAB 9
    • Concrete Structures
    • Eurocode 2

Edit Member Dialog – Tab Shear Reinforcement

Dialog Edit Member with Shear Reinforcement tab, stirrup parameters, and cross-section display of the shear reinforcement in RFEM

The "Edit Member" dialog shows the "Shear Reinforcement" tab for member 1, which is assigned to line 1. The stirrup type is defined as a closed two-leg stirrup A | Ø8.0 @300 with eight legs and material B500A according to EN 1992. The reinforcement parameters include a rebar diameter of 8.0 mm, a distance of 300 mm, and a stirrup reinforcement area of 3.35 cm²/m. The field position extends over the entire member length of 2.100 m with identical arrangement at start and end. The graphic on the right shows the cross-section R_M1 400/450 with longitudinal and shear reinforcement; at the bottom, the stirrup distribution along the member is displayed with the effective length factors ky = 0.59 and kz = 0.59.
  • Shear reinforcement
  • Stirrup reinforcement
  • Edit member
  • Concrete compression
  • Design
  • Shear reinforcement
  • Reinforcement parameter
  • Cross-section
Share