2026-11-13
065651
Defining Effective Lengths of Concrete Member in Edit Member Dialog Box
Edit Member dialog box with Effective Lengths tab for defining the effective length factors ky and kz for concrete design according to EN 1992
The "Edit Member" dialog box shows the "Effective Length Factors" tab, where an effective length factor or equivalent member method is assigned to member 1 for the stability design according to Concrete Design EN 1992 (CEN) 2014-11. In the opened "Edit Member Effective Length Factors" window, the nodal supports at the member start and end are defined with the support type "Fixed all" as well as locked displacements in z and y. The effective length factors for flexural buckling are ky = kz = 0.59. On the right, a 3D model visualizes the member with nodal points and the local axes of coordinates y-z.