This article was translated by Google Translator View original text

Is the statically indeterminate part of internal forces considered due to prestressing force in RF-TENDON?



Answer

Yes, this value is taken into account. The internal forces can also be output accordingly with respect to the prestress (see Figure 1).

Primary Forces: statically determined part of internal forces due to prestress

Secondary Forces: statically indeterminate part of internal forces due to prestress

To display the individual parts, you have to create a new result class (RC) where only the reference of the prestress load is selected.

Keywords

Prestress Determined statically Structurally indeterminate

Downloads

Contact us

Contact to Dlubal

Did you find your question?
If not, contact us via our free e-mail, chat, or forum support, or send us your question via the online form.

+49 9673 9203 0

info@dlubal.com

RFEM Main Program
RFEM 5.xx

Main Program

Structural engineering software for finite element analysis (FEA) of planar and spatial structural systems consisting of plates, walls, shells, members (beams), solids and contact elements

Price of First License
3,540.00 USD
RFEM Concrete Structures
RF-TENDON 5.xx

Add-on Module

Tendon definition in prestressed concrete members

Price of First License
2,060.00 USD