Knowledge Base

Search





Why Dlubal Software?

Solutions

  • More than 45,000 users in 95 countries
  • One software package for all application areas
  • Short learning time and intuitive handling
  • Service provided by experienced engineers
  • Excellent price/performance ratio
  • Flexible modular concept, extensible according to your needs
  • Scalable license system with single and network licenses
  • Proven software used in many well-known projects

Newsletter

Receive information including news, useful tips, scheduled events, special offers, and vouchers on a regular basis.

  1. Figure 01 - Generate 3D Cell

    Modeling Containers by Generating a 3D Cell

    With the function "Generate Model - Members" → "3D Cell", it is very easy to generate containers (shipping containers, office containers, mobile homes, etc.) with regular and irregular distribution of the cells.
  2. Figure 01 - Load Case 1

    Warping Torsion Analysis According to AISC Design Guide 9

    The design of a torsional loaded beam according to AISC Design Guide 9 will be shown based on a verification example. The design will be performed with the RF-STEEL AISC add-on module and the RF-STEEL Warping Torsion module extension with 7 degrees of freedom.
  3. Figure 01 - Original Structure

    Consideration of Possible Contact Between Overlapping Members

    From time to time it happens that two intersecting beams overlap at a short distance.
  4. Figure 01 - Cross-Section

    Stiffened Buckling Panels According to EN 1993-1-5, Section 4.5

    In SHAPE-THIN, it is possible to perform the calculation of stiffened buckling panels according to Section 4.5 of EN 1993-1-5. For stiffened buckling panels, the effective surfaces due to local buckling of the single panels in the plate and in the stiffeners as well as the effective surfaces from the entire panel buckling of the stiffened entire panel have to be considered.
  5. Figure 01 - Model with FE Mesh

    Modeling and Bending Design of Point-Supported Flat Slab

    This article describes how a flat slab is generated as 2D model in RFEM and the loading is applied according to Eurocode 1.
  6. Figure 01 - Generate Catenary

    Assistance Tools for Cable Structures

    RFEM and RSTAB are able to cover a large number of branches in the field of building and construction industry with their generally usable structural frame analysis and FEM programs. The design of cable structures is thus also possible in both software solutions. In the following, some assistance tools for modeling and design will be presented.
  7. Structure for the First Design Step and the Selected Connection

    Influence of Slip of Standardized Joints in Steel Structures

    This article deals with the stiffness of standardized joints according to the DSTV (German Steel Construction Association)/DASt (German Committee for Structural Steelwork) standards, often used in steel construction, and its effects on structural analysis and design results according to DIN EN 1993-1-1.
  8. Figure 01 - Beam to Beam Connection with "Long" Fin Plate

    Fin Plate Connections: Theory and Application

    Fin plate connections are a popular form of pinned steel connections and are commonly used for secondary beams in steel structures. They can be easily used in beam structures arranged on the top edge, e.g. working platforms. Manufacturing expenditures in the workshop as well as the assembly costs on-site are normally manageable. The design seems to be completed easily and quickly, but has to be put into perspective to a certain extent in the following. Moreover, this connection type is basically possible as pinned beam to beam or pinned beam to column connection, whereas the first case is the more common one in design practice.
  9. Figure 01 - Structural System and Cross-Section Dimension According to [1]

    Modeling of Semi-Rigid Composite Beam Made of Timber as Surface Model

    There are several options to calculate a semi-rigid composite beam. They differ primarily in the type of modeling. Whereas the Gamma method ensures a simple modeling, additional efforts are required when using other methods (e.g. shear analogy) for the modeling which are, however, offset by the much more flexible application compared to the Gamma method.
  10. Figure 01 - Snow Load Zones of Germany

    Snow Load on Monopitch and Duopitch Roofs

    In Germany, DIN EN 1991-1-3 with the National Annex DIN EN 1991-1-3/NA regulates the snow loads. The standard applies to civil engineering works at an altitude of up to 1,500 m above sea level.

21 - 30 of 860

Contact us

Contact to Dlubal

Do you have any questions or need advice?
Contact us or find various suggested solutions and useful tips on our FAQ page.

+49 9673 9203 0

info@dlubal.com

First Steps

First steps

We provide hints and tips to help you get started with the main programs RFEM and RSTAB.

Powerful and Capable Software

“I think the software is so powerful and capable that people will really value its power when they get properly introduced to it.”