FAQ 000243 FR

Calculation DYNAM Pro - Forced Vibrations

How do I choose the correct time step for the integration?

Réponse

The correct time step depends on the natural frequency of the system or the frequency of the exciting forces.

To achieve a sufficient precision, the governing period T = 1/f is divided in about 10 steps; that is, the time step Delta t is to be such that Delta t < t/10="1/(10f)" =="" 2="" pi="" (10="" omega).="">

Furthermore, you can specify in this definition point whether the results of each time step are to be shown or, for example, only for each fifth time step.

Contactez-nous

Contactez-nous

Avez-vous trouvé des réponses à vos questions?

Si non, contactez-nous ou envoyez-nous votre question via le formulaire.

+33 1 78 42 91 61

info@dlubal.fr

Premiers Pas

Premiers pas

Ici vous trouverez quelques trucs et astuces pour faciliter votre prise en main des logiciels de calcul de structure RFEM et RSTAB.

Un excellent service de support technique

« Mes compliments à l’équipe du support technique

J’aimerais vous remercier pour votre aide qui m’a été précieuse. Je suis toujours impressionné par la vitesse et la qualité des réponses fournies à mes questions. Je dispose de plusieurs contrats de service avec des acteurs du domaine du calcul de structure, mais votre support technique est de loin le meilleur. »