FAQ 000082 IT

Calculation RFEM RSTAB

Why the program doesn't show any total displacement for result combinations?

Risposta

The different representation of nodal displacements for a load case or a result combination is based on the following:

For a load case, the total member displacement u is calculated from the single displacements u-x, u-y and u-z.

For the result combination, however, it is possible that the individual displacements u-x, u-y and u-z come from different load cases.

Thus, no total displacement u can be calculated.

The individual maximum node deformations would have to be displayed separately, specifying the load cases that lead to those results, and then all again performed for max and min values.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”