FAQ 000233 IT

Display settings RF-CONCRETE

The top and bottom reinforcement seem to be reversed in the graphic.

Risposta

Background: Each surface has a local coordinate system in RFEM (x,y,z).

The coordinates x and y are in-plane, z runs perpendicular to the surface.

The top and bottom side of a surface is determined by the direction of the z-axis.

The direction of the local z-axis determines the bottom side of a surface. Usually, this local z-axis is orientated downwards. Depending on the defined direction of the boundary lines and the sequence in which the lines were clicked., it is also possible that the local z-axis points upwards.

It is easy to correct this. First, display the local surface coordinate system.

To do this, proceed as follows:

Go to the "Display" navigator on the left. Here, you can set all display properties in a tree-like structure.

Open the entries "Model" -> "Surfaces" and select the "Surface Axis Systems x,y,z" check box.

The bottom reinforcement is on the side of the slab, where the z-direction is positive.

To reverse the direction of the local z-axis, click the corresponding surface, and then select the "Reverse axis system" option in the context menu.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”