FAQ 000584 IT

Calculation RF-CONCRETE

What do I have to specify in the add-on module RF-/CONCRETE Columns and RF-/CONCRETE Members if the stability analysis of a frame system made of concrete needs to be a second order-analysis?

Risposta

In RF-/CONCRETE Columns, the design is carried out using the method based on nominal curvature. When verifying the bending resistance, the program internally determines whether a normal design is enough or whether a second-order analysis of the moments is necessary. Therefore, you need to specify the load combinations for the design by using the option for the determination of the internal forces according to geometrically linear static analysis. Moreover, the program determines the eccentricity due to imperfections. Therefore, specify the load cases and combinations without imperfections.

In RF-/CONCRETE Members, the design can be done according to the general design method. Specify the load combinations with the option for the determination of internal forces using the second-order analysis. Also, consider the imperfections. Furthermore, a nonlinear calculation considering the cracked state is necessary.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”