Which criteria are used to defined the "top" and "bottom" reinforcement?

Risposta

If the global Z-axis shows downward, the following definition applies:

"Bottom" is on the surface side showing in the direction of the positive local z-axis of the surface, and "top" on the side of the negative local z-axis.

(Please note that the capital letter for the global axis Z and the lowercase letter for the local surface axis z.)

If the global Z-axis shows upward, the definition is reversed: The bottom reinforcement is on the side of the negative z-axis of the surface, the top reinforcement on the side of the positive z-axis of the surface.

The local surface axes can be turned on in the Display navigator via "Model"->"Surface."

The local z-axes can be quickly reversed:

Right-click the corresponding surface and select "Reverse Local Axis System." In this way, you can unify the reinforcement layers of walls.

It is recommended to define the global Z-axis as downwards when creating the model. In this way, you can ensure that the local z-axes for surfaces in the XY plane show automatically downward and therefore the bottom reinforcements are on the bottom side of the surfaces.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”