Display settings RF-CONCRETE RFEM

I have entered the structural system with the "z-axis directed upwards". Now, there are some directions misrepresented for the definition of suspender and downstand beams and the output of the required reinforcement.

Risposta

The bottom reinforcement for surfaces is defined in direction of the positive local surface axis z. Accordingly, the top reinforcement is defined in direction of the negative local surface axis z. The surface axes can be switched on in the Display navigator by selecting "Model" -> "Surfaces" -> "Surface Axis Systems x,y,z". Alternatively, you can use the surface context menu. The orientation of the local z-axis of a surface can be changed by using the option "Reverse Local Axis System" in the context menu of the surface.

The bottom reinforcement for members is defined on the member side in direction of the positive local member axis z. Accordingly, the top reinforcement is defined in direction of the negative z-axis. To display the member axes, use the Display navigator where you select "Model" -> "Members" -> "Member Axis Systems x,y,z". You can also use the member context menu to check it.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”