Results RF-STEEL EC3 STEEL EC3 8.xx

When analyzing a member in RF-/STEEL EC3, the result windows show a difference between the moments listed in design internal forces and the moments used in the design. What has caused this difference?

Risposta

If this difference appears in the design Bending and Compression according to 6.3.3., you can find the explanation in Eurocode 1993-1-1, Cl. 6.3.3. (4). In the explanation of variables, there is written: "the design values of the compression force and the maximum moments". The word "maximum" should be emphasized here. Therefore, the results display the corresponding axial force in the case of design by x‑locations. However, this force applies the maximal moments on the member or set of members.

Contattaci

Contattaci

Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.

+39 051 9525 443

info@dlubal.it

Primi passi

Primi passi

Offriamo suggerimenti e consigli utili per aiutarti a familiarizzare con i programmi principali RFEM e RSTAB.

Veramente la miglior assistenza tecnica

“Un sentito grazie per le utili informazioni.

Vorrei fare un complimento al vostro team di assistenza tecnica. Sono sempre sorpreso da come trovate le risposte alle mie domande velocemente e professionalmente. Nel settore dell'analisi strutturale, uso diversi software compresi di contratti di servizio, ma la vostra assistenza è di gran lunga la migliore.”