FAQ 002120 IT

Add-on modules FOUNDATION Pro RF-FOUNDATION Pro 8.xx

Where can I specify in RF-/FOUNDATION Pro whether the loading for design of foundation rotation according to DIN EN 1997-1 results from a permanent action or from a combination of permanent and variable actions?


For this, open the "1.4 Loading" window in the add-on module abnd select the "Characteristic Values" tab. If you have selected the design according to EN EN 1997-1 in the "1.1 General Data" window, you can set for each load case or load combination selected for design whether a "permanent action" or a "permanent + variable action" is concerned. You can assign the actions by moving the corresponding entry in the "Selected for Design" list.

Parole chiave

characteristic values, foundation rotation



Hai trovato la risposta alla tua domanda? In caso contrario, contattaci o inviaci la tua domanda utilizzando il modulo online.