FAQ 000740 PT

Calculation RF-CONCRETE

Which criteria are used to defined the "top" and "bottom" reinforcement?

Resposta

If the global Z-axis shows downward, the following definition applies:

"Bottom" is on the surface side showing in the direction of the positive local z-axis of the surface, and "top" on the side of the negative local z-axis.

(Please note that the capital letter for the global axis Z and the lowercase letter for the local surface axis z.)

If the global Z-axis shows upward, the definition is reversed: The bottom reinforcement is on the side of the negative z-axis of the surface, the top reinforcement on the side of the positive z-axis of the surface.

The local surface axes can be turned on in the Display navigator via "Model"->"Surface."

The local z-axes can be quickly reversed:

Right-click the corresponding surface and select "Reverse Local Axis System." In this way, you can unify the reinforcement layers of walls.

It is recommended to define the global Z-axis as downwards when creating the model. In this way, you can ensure that the local z-axes for surfaces in the XY plane show automatically downward and therefore the bottom reinforcements are on the bottom side of the surfaces.

Contacto

Contacto da Dlubal

Encontrou a sua pergunta? Se não for o caso, entre em contacto connosco ou envie-nos a sua questão através do formulário online.

+49 9673 9203 0

(falamos português)

info@dlubal.com

Primeiros passos

first-steps

Aqui damos-lhe algumas dicas e informações úteis que o ajudam a familiarizar-se mais rapidamente com os programas principais RFEM e RSTAB.

O vosso apoio técnico é de longe o melhor

“Muito obrigado por toda a informação.

Gostaria de elogiar a equipa de apoio ao cliente. Fico sempre surpreendido com a rapidez e o profissionalismo com que as questões são respondidas. Na área da análise de estruturas, utilizo vários softwares inclusive com contratos de assistência, mas o vosso apoio técnico é de longe o melhor.”