FAQ 002031 PT

Modeling | Loading RFEM RSTAB 5.xx 8.xx

I have generated a trapezoidal area load. When displaying the load separately, I can see only constant loads on members. What happened and can I change that?

Resposta

The reason is that the "Correction of Generated Loads" is inactive and thus, only intermediate values are determined. To change that, select the "According to moment equilibrium of total loads and generated member loads" option in detail settings of the load generator (see picture).

For more information about load correction, see RFEM/RSTAB manual, Chapter 11.8.1.

Palavra chave

area load, trapezoidal load, load generator

Contacto

Contacto da Dlubal

Encontrou a sua pergunta? Se não for o caso, entre em contacto connosco ou envie-nos a sua questão através do formulário online.