Módulos adicionais FRAME-JOINT Pro RF-FRAME-JOINT Pro 8.xx 5.xx

After the calculation start, RF-/FRAME-JOINT Pro appears in the "1.2 Cross-Sections" window and shows the following error message: "The value is out of the allowed range. Design value: 0.00 - Min. value: 3.00". However, I cannot detect a mistake.

Resposta

Columns consist of a parametrized I-section (welded section). To use such a cross-section in RF-/FRAME-JOINT Pro, it is necessary to enter the web weld thickness as well. On the one hand, the weld in tension area is designed in RF-/FRAME-JOINT Pro; on the other hand, your thickness is also used in the calculation of effective lengths of the T-stub.

Palavra chave

error message. warning, value

Contacto

Contacto da Dlubal

Encontrou a sua pergunta? Se não for o caso, entre em contacto connosco ou envie-nos a sua questão através do formulário online.

+49 9673 9203 0

(falamos português)

info@dlubal.com

RSTAB Ligações
FRAME-JOINT Pro 8.xx

Módulo adicional

Dimensionamento de ligações de nós de pórticos rígidos de acordo com o Eurocódigo 3

RFEM Ligações
RF-FRAME-JOINT Pro 5.xx

Módulo adicional

Dimensionamento de ligações de nós de pórticos rígidos de acordo com o Eurocódigo 3