For wall ends and wall corners, no soil contact stresses are deducted in RF-PUNCH pro, even though the type "Foundation" has been set. It is also nowhere possible to define that the soil contact stresses should be deducted. Why does this happen?

Resposta

If you perform a punching shear design for a wall corner or a wall end at a floor slab or foundation plate, this entry is not necessary.

Since the punching load is determined at a wall corner or a wall end from the shear forces in the control perimeter when performing the punching shear design, the ratio of the surface load is missing anyway within the control perimeter (up to the load application). Therefore, this entry is also not necessary in the 1.5 dialog box.

If you, however, perform the punching shear design for a single column at a foundation plate with the punching load from the normal force of this column, you can enter the "Deductible Surface Load" at the end of the dialog box "1.5 Nodes of Punching Shear - Node of Punching Shear - Details" which allows to determine ΔVEd.

Palavra chave

punching, wall end, wall corner, foundation plate, floor slab, soil contact pressure, deductible surface load, favorable surface load

Contacto

Contacto da Dlubal

Encontrou a sua pergunta? Se não for o caso, entre em contacto connosco ou envie-nos a sua questão através do formulário online.

+49 9673 9203 0

(falamos português)

info@dlubal.com

RFEM Estruturas de Betão Armado
RF-PUNCH Pro 5.xx

Módulo adicional

Verificação ao punçoamento de fundações e lajes apoiadas em nós ou linhas

Preço de primeira licença
760,00 USD
RFEM Programa principal
RFEM 5.xx

Programa principal

Software de engenharia estrutural para análises de elementos finitos (AEF) de estruturas planas e espaciais constituídas por lajes, paredes, vigas, sólidos e elementos de contacto

Preço de primeira licença
3.540,00 USD