FAQ 005224 | I am having trouble with the design of a steel structure. For a singly symmetric cross-section (UPE), the program cannot perform the stability analysis. It reports that the
FAQ 005224 | I am having trouble with the design of a steel structure. For a singly symmetric cross-section (UPE), the program cannot perform the stability analysis. It reports that the
2024-05-30
030401

For singly symmetric cross-sections, use the boundary conditions and the 2D general method according to EN 1993‑1‑1, 6.3.4.

FAQ 005224 | I am having trouble with the design of a steel structure. For a singly symmetric cross-section (UPE), the program cannot perform the stability analysis. It reports that the

Used in
  • Unsymmetrical Cross-Section (UPE)
Share