2026-07-10
063802
RFEM 6 Design Check Details SD0206.01 – Flexural Design of Foundation Plate in x-Direction
Design check details SD0206.01 flexure foundation plate x-direction ACI 318 utilization 0.975
Screenshot of the design check details in RFEM 6 for check SD0206.01 per ACI 318 (2019): flexural design of the foundation plate in the positive x-direction on the bottom side according to section 13.2.6.4. The design check ratio η is 0.975.