2026-09-15
064862
Wind Pressures on the Tower from Wind Simulation in RFEM
Wind pressure distribution on a stair tower and footbridge calculated with the Wind Simulation add-on in RFEM
Wind pressures on the surfaces of the tower and the footbridge, calculated with the Wind Simulation add-on for one of the wind load cases. The pressures range from 0.75 to -0.72 kN/m², and the resulting total drag force reaches 217.8 kN. Results of this kind formed the basis for the wind load combinations that govern the design of the ground anchors. Model: © StruDesign OÜ | Screenshot: © Dlubal Software s.r.o.
3D Model
No Download Possible
Customer Project / View Only
More About 3D Model
Specifications
| Number of Nodes | 645 |
| Number of Lines | 826 |
| Number of Members | 303 |
| Number of Surfaces | 84 |
| Number of Solids | 0 |
| Number of Load Cases | 15 |
| Number of Load Combinations | 84 |
| Number of Result Combinations | 0 |
| Total Weight | 786.546 tons |
| Dimensions (Metric) | 79.232 x 36.529 x 25.336 m |
| Dimensions (Imperial) | 259.95 x 119.85 x 83.12 feet |