FAQ 000125 RU

Вычисление RFEM RSTAB

In the "Effective Lengths" tab of the "Edit Member" dialog box, there is the check box "Check exceeding of critical buckling load." If I select it, what is the effect on the calculation in RSTAB or RFEM?

Ответ

The effective length factors that you can change in the "Effective Lengths" tab are not considered in the determination of internal forces in RSTAB and RFEM.

These values are presettings for add-on modules used for performing stability analyses, for example STEEL EC3 or TIMBER Pro. The values will be considered in the modules.

The check box "Check exceeding of critical buckling load" has an influence if the critical load is reached. If this happens, this member fails and the program shows an instability message.

Контакты

Свяжитесь с Dlubal

На ваш вопрос уже ответили? Если нет, свяжитесь с нами или отправьте ваш вопрос с помощью онлайн-формуляра.

+49 9673 9203 0

info@dlubal.com

RFEM Основная программа
RFEM 5.xx

Основная программа

Программное обеспечение для расчета конструкций методом конечных элементов (МКЭ) плоских и пространственных конструктивных систем, состоящих из плит, стен, оболочек, стержней (балок), тел и контактных элементов

RSTAB Основная программа
RSTAB 8.xx

Основная программа

Программное обеспечение для расчета конструкций рам, балок и ферм, выполняющее линейные и неьинейные расчеты внутренних сил, деформаций и опорных реакций