分析暴风雨“尤尼斯”作用下穹顶建筑的连续损伤
注释:
该研究调查了暴风雨对 Millennium Dome 膜结构的损伤。 它突出了附近的结构如何放大风荷载,增加结构的易损性。 该研究使用 CFD 模拟,强调需要考虑城市和环境因素。 研究结果需要对轻型膜结构采取弹性设计策略。
论文摘要:
在中欧北部和西北部造成的影响凸显了轻型结构在极端风荷载作用下的弱点,特别是那些使用张拉膜面的结构。 Iconic examples like the Millennium Dome—designed by the Richard Rogers Partnership and Imagination—symbolize modern architecture with their innovative, lightweight canopy systems aligned with celestial paths. 为此,本论文的研究内容是,探究强暴风雨引起的风荷载是如何对这种张拉膜结构造成破坏的,重点是表面性能退化的四个不同阶段。
The research further investigates how surrounding urban structures, like the Aura Tower, influence local wind behavior—specifically, amplifying wind speeds and suction pressures in the range of 45 to 55 meters per second, which can induce significant structural harm. 该研究表明,通过计算流体动力学(CFD)模拟和详细的风压系数分析表明,TMS 结构在设计中必须仔细考虑城市规划和自然环境因素,以确保其具有抵御动态风荷载的能力。
The findings strongly suggest that neighboring high-rise developments can severely exacerbate the wind loading on lightweight tensile membranes, making them prone to progressive tearing, membrane fluttering, and eventual catastrophic failure. 强调了在建筑和土木工程设计过程中采用湍流模型和准确的环境荷载估算的必要性。 这些都是为了帮助 TMS 在人口越来越密集的城市中的应用,特别是在气候变化和更加频繁的极端天气事件的威胁越来越大的情况下。