FAQ 002039 ZH

Modeling | Structure RFEM RSTAB 5.xx 8.xx

In the case of compound timber cross-sections, it is possible to consider the "gamma" factor. How can I determine it?

回答

You can determine the "gamma factor" according to EN 1995-1-1, Annex B. Among others, it depends on the slip modulus of a fastener and its distance as well as span length. However, this method is limited. Therefore, you can also create a pure member model and read or design the internal forces directly there. For more information, read the following Dlubal Blog articles: Alternative to Gamma Method: Semi-Rigid Composite Beam as Framework Model, Part 1 Alternative to Gamma Method: Semi-Rigid Composite Beam as Framework Model, Part 2

联系我们

联系 Dlubal

您找到您的问题和解答了吗?如果没有,请联系我们或者把您的问题通过网上表格递交给我们。

+49 9673 9203 0

(可要求接中文热线)

info@dlubal.com

初学者

Erste Schritte

我们在这里为初学者提供了重要的提示和建议,以便用户更加容易快速的掌握使用我们的基本软件 RFEM 和 RSTAB。

优秀的技术支持

“谢谢你们提供的实用信息。