FAQ 002039 PL

Modeling | Structure RFEM RSTAB 5.xx 8.xx

In the case of compound timber cross-sections, it is possible to consider the "gamma" factor. How can I determine it?

Odpowiedź

You can determine the "gamma factor" according to EN 1995-1-1, Annex B. Among others, it depends on the slip modulus of a fastener and its distance as well as span length. However, this method is limited. Therefore, you can also create a pure member model and read or design the internal forces directly there. For more information, read the following Dlubal Blog articles: Alternative to Gamma Method: Semi-Rigid Composite Beam as Framework Model, Part 1 Alternative to Gamma Method: Semi-Rigid Composite Beam as Framework Model, Part 2

Kontakt

Kontakt do Dlubal

Jeśli nie znaleźli Państwo odpowiedzi na pytania, mogą Państwo skontaktować się z nami lub wysłać zapytanie za pomocą formularza.

+48 (32) 782 46 26

+48 730 358 225

info@dlubal.pl

Pierwsze kroki

Pierwsze kroki

Oferujemy wskazówki, które pomogą Państwu rozpocząć pracę z programami RFEM i RSTAB

Najlepsze wsparcie klienta

„Bardzo dziękuję za użyteczną informację. 

Chciałbym skomplementować Wasz zespół ds. wsparcia technicznego. Zawsze jestem pod wrażeniem, jak szybko i profesjonalnie udzielane są odpowiedzi. Jesli chodzi o oprogramowanie do analizy statycznej, korzystam z kilku programów wraz z umową serwisową, ale Wasze wsparcie techniczne jest zdecydowanie najlepsze.”