Does SUPER-RC superimpose only the internal forces from models that have already been saved? Or also from models that are still open, have only recently been calculated and whose results are available only as temporary files?


When you want to define a super combination, choose the relevant models among the models of the current project by mouse click.

Then, select one or several LC types from the existing LCs, COs and RCs and add them to the SC using the buttons [Add with "+"] or [Add with "OR"].

For the calculation of the super combination it is not necessary that the results of the other open models are available. The needed load cases of the contained models will be calculated once the calculation is performed.

The other models contained in the super combination also do not need to be open for the calculation. If you have calculated the results in the opened models only recently, the super combination will be calculated, too, of course.