FAQ 002042 ES

Results RF-STEEL EC3 STEEL EC3 8.xx

When analyzing a member in RF-/STEEL EC3, the result windows show a difference between the moments listed in design internal forces and the moments used in the design. What has caused this difference?


If this difference appears in the design Bending and Compression according to 6.3.3., you can find the explanation in Eurocode 1993-1-1, Cl. 6.3.3. (4). In the explanation of variables, there is written: "the design values of the compression force and the maximum moments". The word "maximum" should be emphasized here. Therefore, the results display the corresponding axial force in the case of design by x‑locations. However, this force applies the maximal moments on the member or set of members.

Contacte con nosotros

Contacte con Dlubal Software

¿Ha encontrado su pregunta?

Si no es así, contáctenos o envíe su pregunta mediante el formulario en línea.



Primeros pasos